Standard Rack Assembly

– Fully sheeted duct furnaces mounted in a 16-gauge galvanized steel frame.
– Provides listed temperature rise and air side pressure drop performance.
– Each furnace includes an individual shutoff valve, flexible gas connector & union piped to properly sized supply header.
– Condensate drains pre-piped to a common header.
– Easy removal of any single duct furnace.
– All controls prewired to a sequencer for system control.
– Customer only needs to provide Power, “Call for Heat” and a 0-10 VDC signal.

Outdoor Venting Kit

– Vent riser assembly with integral rain cap.
– Provides proper venting of flue gases and prevents flue gas recirculation into burner combustion air supply.


Application Guidelines Product Specification User Guidelines OEM Instructions Submittal / Order Information

Note: You must be logged in to view CAD, Gas Train and Wiring Diagram files.
Model NumberPDFAlt PDFPDF of Gas TrainPDF of Wiring DiagramMax Input MBHMax Output MBHMin Input MBHMin Output MBHNat. Gas Turndown RatioMax Ind. HX Input# of HX'sMax CFMMax APD @ Min RiseMax Temp RiseMin CFMMin APD @ Max RiseDim ADim BDim CDim DWeight (Lbs.)Total Amps 120VTotal Amps 208V 230V
HDA-VHX-150-300-OPDFPDFPDF3002433024.310 to 1150275000.4410022500.0239.5729.9844.6616.547885
HDA-VHX-200-400-OPDFPDFPDF4003244032.410 to 12002100000.7810030000.0639.5729.9844.6616.550385
HDA-VHX-150-450-OPDFPDFPDF4503644524.315 to 11503112500.4410033750.0258.5429.9844.6616.5717127.5
HDA-VHX-250-500-OPDFPDFPDF5004055040.510 to 12502125000.7910037500.0746.0729.9844.6616.551885
HDA-VHX-300-600-OPDFPDFPDF6004866048.610 to 13002150000.810045000.0752.5729.9844.6616.556185
HDA-VHX-200-600-OPDFPDFPDF6004866032.415 to 12003150000.7810045000.0658.5429.9844.6616.5755127.5
HDA-VHX-350-700-OPDFPDFPDF7005677056.710 to 13502175000.8110052500.0859.0729.9844.6616.561985
HDA-VHX-250-750-OPDFPDFPDF7506087540.515 to 12503187500.7910056250.0768.2929.9844.6616.5779127.5
HDA-VHX-400-800-OPDFPDFPDF8006488064.810 to 14002200000.8810060000.0865.5729.9844.6616.567285
HDA-VHX-300-900-OPDFPDFPDF9007299048.615 to 13003225000.810067500.0778.0429.9844.6616.5829127.5
HDA-VHX-500-1000-OPDFPDFPDF10008101008110 to 15002250000.9610075000.0978.5729.9844.661876810
HDA-VHX-350-1050-OPDFPDFPDF105085010556.715 to 13503262500.8110078750.0887.7929.9844.6616.5908127.5
HDA-VHX-600-1200-OPDFPDFPDF120097212097.210 to 16002300001.0310090000.191.5729.9844.661882910
HDA-VHX-400-1200-OPDFPDFPDF120097212064.815 to 14003300000.8810090000.0897.5429.9844.6616.5988127.5
HDA-VHX-500-1500-OPDFPDFPDF150012151508115 to 15003375000.96100112500.09117.0429.9844.66181160157.5
HDA-VHX-600-1800-OPDFPDFPDF1800145818097.215 to 16003450001.03100135000.1136.5429.9844.66181220157.5
Note: For Propane gas, turndown is 60% of stated natural gas turndown.