Standard Rack Assembly

– Fully sheeted duct furnaces mounted in a 16-gauge galvanized steel frame.
– Provides listed temperature rise and air side pressure drop performance.
– Each furnace includes an individual shutoff valve, flexible gas connector & union piped to properly sized supply header.
– Condensate drains pre-piped to a common header.
– Easy removal of any single duct furnace.
– All controls prewired to a sequencer for system control.
– Customer only needs to provide Power, “Call for Heat” and a 0-10 VDC signal.

Outdoor Venting Kit

– Vent riser assembly with integral rain cap.
– Provides proper venting of flue gases and prevents flue gas recirculation into burner combustion air supply.

Application Guidelines Product Specification User Guidelines OEM Instructions Submittal / Order Information

Note: You must be logged in to view CAD, Gas Train and Wiring Diagram files.
Model NumberPDFAlt PDFPDF of Gas TrainPDF of Wiring DiagramMax Input MBHMax Output MBHMin Input MBHMin Output MBHNat. Gas Turndown RatioMax Ind. HX Input# of HX'sMax CFMMax APD @ Min RiseMax Temp RiseMin CFMMin APD @ Max RiseDim ADim BDim CDim DWeight (Lbs.)Total Amps 120VTotal Amps 208V 230V
HDB-VHX-180-360-OPDFPDFPDF360292362910 to 1180290000.119030000.0142.3721.1378.417.1354085
HDB-VHX-200-400-OPDFPDFPDF400324403210 to 12002100000.139033330.0242.3721.1378.417.1354085
HDB-VHX-225-450-OPDFPDFPDF450365453610 to 12252112500.169037500.0248.8721.1378.417.1354085
HDB-VHX-250-500-OPDFPDFPDF500405504110 to 12502125000.159041670.0248.8721.1378.417.1354085
HDB-VHX-270-540-OPDFPDFPDF540437544410 to 12702135000.139045000.0255.3721.1378.417.1358085
HDB-VHX-180-540-OPDFPDFPDF540437362915 to 11803135000.119045000.0162.7421.1378.417.13760127.5
HDB-VHX-300-600-OPDFPDFPDF600486604910 to 13002150000.169050000.0255.3721.1378.417.1358085
HDB-VHX-200-600-OPDFPDFPDF600486403215 to 12003150000.139050000.0262.7421.1378.417.13760127.5
HDB-VHX-315-630-OPDFPDFPDF630510635110 to 13152157500.159052500.0261.8721.1378.417.1362285
HDB-VHX-225-675-OPDFPDFPDF675547453615 to 12253168750.169056250.0272.4921.1378.417.13760127.5
HDB-VHX-350-700-OPDFPDFPDF700567705710 to 13502175000.189058330.0261.8721.1378.417.1362685
HDB-VHX-360-720-OPDFPDFPDF720583725810 to 13602180000.169060000.0268.3721.1378.417.1367485
HDB-VHX-375-750-OPDFPDFPDF750608756110 to 13752187500.189062500.0268.3721.1378.417.1367485
HDB-VHX-250-750-OPDFPDFPDF750608504115 to 12503187500.159062500.0272.4921.1378.417.13813127.5
HDB-VHX-400-800-OPDFPDFPDF800648806510 to 14002200000.29066670.0268.3721.1378.417.1367485
HDB-VHX-270-810-OPDFPDFPDF820664554515 to 12703205000.139068330.0282.2421.1378.417.13870127.5
HDB-VHX-300-900-OPDFPDFPDF900729604915 to 13003225000.169075000.0282.2421.1378.417.13817127.5
HDB-VHX-315-945-OPDFPDFPDF945765635115 to 13153236250.159078750.0291.9921.1378.417.13888127.5
HDB-VHX-500-1000-OPDFPDFPDF10008101008110 to 15002250000.219083330.0281.3723.6378.420.1376810
HDB-VHX-350-1050-OPDFPDFPDF1050851705715 to 13503262500.189087500.0291.9921.1378.417.13888127.5
HDB-VHX-360-1080-OPDFPDFPDF1080875725815 to 13603270000.169090000.02101.7421.1378.417.131015127.5
HDB-VHX-375-1125-OPDFPDFPDF1125911756115 to 13753281250.189093750.02101.7421.1378.417.131015127.5
HDB-VHX-600-1200-OPDFPDFPDF12009721209710 to 16002300000.2390100000.0394.3723.6378.420.1382910
HDB-VHX-400-1200-OPDFPDFPDF1200972806515 to 14003300000.290100000.02101.7421.1378.417.131015127.5
HDB-VHX-500-1500-OPDFPDFPDF150012151008115 to 15003375000.2190125000.02121.2423.6378.420.131160157.5
HDB-VHX-600-1800-OPDFPDFPDF180014581209715 to 16003450000.2390150000.03140.7423.6378.420.131220157.5
Note: For Propane gas, turndown is 60% of stated natural gas turndown.