– Fully sheeted duct furnaces mounted in a 16-gauge galvanized steel frame.
– Provides listed temperature rise and air side pressure drop performance.
– Each furnace includes an individual shutoff valve, flexible gas connector & union piped to properly sized supply header.
– Condensate drains pre-piped to a common header.
– Easy removal of any single duct furnace.
– All controls prewired to a sequencer for system control.
– Customer only needs to provide Power, “Call for Heat” and a 0-10 VDC signal.

Application Guidelines Product Specification User Guidelines OEM Instructions Submittal / Order Information

Note: You must be logged in to view CAD, Gas Train and Wiring Diagram files.
Model NumberPDFAlt PDFPDF of Gas TrainPDF of Wiring DiagramMax Input MBHMax Output MBHMin Input MBHMin Output MBHNat. Gas Turndown RatioMax CFMMax APD @ Min RiseMax Temp RiseMin CFMMin APD @ Max RiseDim ADim BDim CDim DWeight (Lbs.)Total Amps 120VTotal Amps 208V 230VDim EDim F
HDB-VHX-180-360PDFPDFPDF360292362910 to 190000.119030000.0142.3721.1378.417.1351285
HDB-VHX-200-400PDFPDFPDF400324403210 to 1100000.139033330.0242.3721.1378.417.1351285
HDB-VHX-225-450PDFPDFPDF450365453610 to 1112500.169037500.0248.8721.1378.417.1351285
HDB-VHX-250-500PDFPDFPDF500405504110 to 1125000.159041670.0248.8721.1378.417.1351285
HDB-VHX-270-540PDFPDFPDF540437544410 to 1135000.139045000.0255.3721.1378.417.1355285
HDB-VHX-180-540PDFPDFPDF540437362915 to 1135000.119045000.0162.7421.1378.417.13718127.5
HDB-VHX-300-600PDFPDFPDF600486604910 to 1150000.169050000.0255.3721.1378.417.1355285
HDB-VHX-200-600PDFPDFPDF600486403215 to 1150000.139050000.0262.7421.1378.417.13718127.5
HDB-VHX-315-630PDFPDFPDF630510635110 to 1157500.159052500.0261.8721.1378.417.1359485
HDB-VHX-225-675PDFPDFPDF675547453615 to 1168750.169056250.0272.4921.1378.417.13718127.5
HDB-VHX-350-700PDFPDFPDF700567705710 to 1175000.189058330.0261.8721.1378.417.1359485
HDB-VHX-360-720PDFPDFPDF720583725810 to 1180000.169060000.0268.3721.1378.417.1364285
HDB-VHX-375-750PDFPDFPDF750608756110 to 1187500.189062500.0268.3721.1378.417.1364285
HDB-VHX-250-750PDFPDFPDF750608504115 to 1187500.159062500.0272.4921.1378.417.13768127.5
HDB-VHX-400-800PDFPDFPDF800648806510 to 1200000.29066670.0268.3721.1378.417.1364285
HDB-VHX-270-810PDFPDFPDF820664554515 to 1205000.139068330.0282.2421.1378.417.13828127.5
HDB-VHX-300-900PDFPDFPDF900729604915 to 1225000.169075000.0282.2421.1378.417.13773127.5
HDB-VHX-315-945PDFPDFPDF945765635115 to 1236250.159078750.0291.9921.1378.417.13836127.5
HDB-VHX-500-1000PDFPDFPDF10008101008110 to 1250000.219083330.0281.3723.6378.420.1373310
HDB-VHX-350-1050PDFPDFPDF1050851705715 to 1262500.189087500.0291.9921.1378.417.13836127.5
HDB-VHX-360-1080PDFPDFPDF1080875725815 to 1270000.169090000.02101.7421.1378.417.13963127.5
HDB-VHX-375-1125PDFPDFPDF1125911756115 to 1281250.189093750.02101.7421.1378.417.13963127.5
HDB-VHX-600-1200PDFPDFPDF12009721209710 to 1300000.2390100000.0394.3723.6378.420.1377310
HDB-VHX-400-1200PDFPDFPDF1200972806515 to 1300000.290100000.02101.7421.1378.417.13963127.5
HDB-VHX-500-1500PDFPDFPDF150012151008115 to 1375000.2190125000.02121.2423.6378.420.131076157.5
HDB-VHX-600-1800PDFPDFPDF180014581209715 to 1450000.2390150000.03140.7423.6378.420.131136157.5
Note: For Propane gas, turndown is 60% of stated natural gas turndown.