Configurations with 30-100°F Temp Rise – Front Exhaust

Product Specification Application Guidelines Product Manual Submittal / Order Information

Note: You must be logged in to view CAD files.
Model NumberPDFMax Input MBHMax Output MBHBurner Model #Burner Turn DownBurner Max BtuBurner Min BTUWeight (Lbs.)Max CFMMax APD @ Min RiseMin CFMMin APD @ Max Rise
HF750-VF-GS1-FA B938760GS130 to 11500000375001413234571.4370370.13
HF1000-VF-GS1-FA B12351000GS130 to 11500000375001742308641.7592590.16
HF1250-VF-GS1-FA B15311240GS130 to 11500000375001873382722.71114810.24
HF1500-VF-GS2-FA B18521500GS230 to 12500000625001920462962.26138890.2
HF1750-VF-GS2-FA B22221800GS230 to 12500000625002056555562.57166670.23
HF2000-VF-GS2-FA B24692000GS230 to 12500000625002146617284.64185190.41
HF2500-VF-GS3-FA B29632400GS330 to 137500001250002654740743.62222220.32
HF3000-VF-GS3-FA B37043000GS330 to 137500001250003276925932.87277780.25
HF4000-VF-GS4-FA B49384000GS430 to 1500000015000042521234575.5370370.49
BOM disclaimer:
Burner technical data is provided for typical standard burner and is subject to change without notice by the burner manufacturer.

Configurations with 30-100°F Temp Rise – Top Exhaust

Product Specification Application Guidelines Product Manual Submittal / Order Information

Model NumberPDFMax Input MBHMax Output MBHBurner Model #Burner Turn DownBurner Max BtuBurner Min BTUDim AWeight (Lbs.)Max CFMMax APD @ Min RiseMin CFMMin APD @ Max Rise
HF750-VF-GS1-TA B938760GS130 to 115000003750050.531413234571.4370370.13
HF1000-VF-GS1-TA B12351000GS130 to 115000003750056.361742308641.7592590.16
HF1250-VF-GS1-TA B15311240GS130 to 115000003750056.361873382722.71114810.24
HF1500-VF-GS2-TA B18521500GS230 to 125000006250056.361920462962.26138890.2
HF1750-VF-GS2-TA B22221800GS230 to 125000006250056.362056555562.57166670.23
HF2000-VF-GS2-TA B24692000GS230 to 125000006250056.362146617284.64185190.41
HF2500-VF-GS3-TA B29632400GS330 to 1375000012500061.362654740743.62222220.32
HF3000-VF-GS3-TA B37043000GS330 to 1375000012500065.863276925932.87277780.25
HF4000-VF-GS4-TA B49384000GS430 to 1500000015000065.8642521234575.5370370.49
BOM disclaimer:
Burner technical data is provided for typical standard burner and is subject to change without notice by the burner manufacturer.

Stacked Models

Product Specification Application Guidelines Product Manual Submittal / Order Information

Note: You must be logged in to view CAD files.
Model NumberPDFMax Input MBHMax Output MBHBurner Model #Burner Turn DownBurner Max BtuBurner Min BTUMin APD @ Max Rise
HF750-VF-GS1-F-X2TA B18771520GS130 to 11500000375000.13
HF1000-VF-GS1-F-X2TA B24692000GS130 to 11500000375000.16
HF1250-VF-GS1-F-X2TA B30622480GS130 to 11500000375000.24
HF1500-VF-GS2-F-X2TA B37043000GS230 to 12500000625000.2
HF1750-VF-GS2-F-X2TA B44443600GS230 to 12500000625000.23
HF2000-VF-GS2-F-X2TA B49384000GS230 to 12500000625000.41
HF2500-VF-GS3-F-X2TA B59264800GS330 to 137500001250000.32
HF3000-VF-GS3-F-X2TA B74076000GS330 to 137500001250000.25
HF4000-VF-GS4-F-X2TA B98778000GS430 to 150000001500000.49
BOM disclaimer: Burner technical data is provided for typical standard burner and is subject to change without notice by the burner manufacturer.
Model NumberPDFMax Input MBHMax Output MBHBurner Model #Burner Turn DownBurner Max BtuBurner Min BTUWeight (Lbs.)Max CFMMax APD @ Min RiseMin CFMMin APD @ Max Rise
HF750-VF-GS1-T-F-X2TA B18771520GS130 to 11500000375002826469141.43140740.13
HF1000-VF-GS1-T-F-X2TA B24692000GS130 to 11500000375003484617281.75185180.16
HF1250-VF-GS1-T-F-X2TA B30622480GS130 to 11500000375003746765442.71229620.24
HF1500-VF-GS2-T-F-X2TA B37043000GS230 to 12500000625003840925922.26277780.2
HF1750-VF-GS2-T-F-X2TA B44443600GS230 to 125000006250041121111122.57333340.23
HF2000-VF-GS2-T-F-X2TA B49384000GS230 to 125000006250042921234564.64370380.41
HF2500-VF-GS3-T-F-X2TA B59264800GS330 to 1375000012500053081481483.62444440.32
HF3000-VF-GS3-T-F-X2TA B74076000GS330 to 1375000012500065521851862.87555560.25
HF4000-VF-GS4-T-F-X2TA B98778000GS430 to 1500000015000085082469145.5740740.49
BOM disclaimer: Burner technical data is provided for typical standard burner and is subject to change without notice by the burner manufacturer.