Heatco ensures INNOVATION, QUALITY, and RELIABILITY in all of our products.
Note: For the quickest service regarding parts orders/requests, please email orders@heatco.com.

Used on HDB-HH with individual BTU 200-400 adapter has 15 degree offset for 96″ cabinet

(Replaced by FA-2-6) Used in conjunction with HMFA-3 on outdoor flue riser applications with 2″ thick vestibule

Used on HMA/HDA HMB/HDB 200-400, HMG/HDG200-400 and HMD/HDD175-200 in power vent applications
HMFA-26-1 thru 9
View PDF or CAD

Used on HMA/HDA HMB/HDB200-400, HMG/HDG250-400 and HMD/HDD175-200 in power vent applications
HMFA-12-5-Insulated
View PDF or CAD

Extension used with HMFA-12 on HMT/HDT1000-1250 and HMB/HDB HMA/HDA500-600

7″ Adapter with 2.5″ offset | Used on HMA/HDA HMB/HDB 500-600 and HMT/HDT1000-1250

Used in with HMFA-3 on outdoor flue riser applications where 6″ added depth is needed

Used with HMFA-3 on indoor common flue riser precision vent applications
HMSK8
Drawings Unavailable

8in Star Cap
HMSK5
Drawings Unavailable

5in Star Cap
HMSK6
Drawings Unavailable

6in Star Cap
HMES2270-0885

Air Pressure Switch, Single, 2.0
HMES2331-1037

Air Pressure Switch, Single, 1.00 +/-.05″ WC
HMES2089-1011

Air Pressure Switch, Single, .35 +/-.05″ WC
HMES2120-0385

Air Pressure Switch, Single, .50 +/- .05
HMES2089-0658

Air Pressure Switch,Single,1.3 +/- .06
HMES2086-0708

Air Pressure Switch,Single, .9 +/- .05
HMES2089-0307

Air Pressure Switch,Single, 1.5 +/- .06
HMES2089-0308

Air Pressure Switch,Single,1.1 +/- .05
HMES2089-1012

Air Pressure Switch, Single, .60 +/-.05″ WC
HMES2090-0309

Single, .5 +/- .05 PF, Indoor HE Units
Air Flow Pressure Switch Kit

HMRFS-4100-040(switch) and (1) HM8457K536(probe)
HMESA2088-0306

Air Pressure Switch, Dual, .35 Low(ES2087-0305), 1.1 High(ES2086-0304)
HMESA2088-0739

Air Pressure Switch, Dual, .35 Low(ES2087-0305), 1.3 High(ES2086-0679)
HMESA2093-0312

Air Pressure Switch, Dual, .35 Low(ES2092-0311), 1.5 High(ES2091-0310)
HMESA2088-0678

Air Pressure Switch, Dual, -.6Low(ES2087-0680), -1.3High(ES2086-0679)
HMESA2088-0706

REPLACED WITH HMESA2088-0306. Dual, .35 +/- .05 Low, .9 +/-.05 High
HMESA2088-0974

Air Pressure Switch, Dual, .6 Low(ES2087-0680), .9 High(ES2086-0708)
HMESA2088-0973

Air Pressure Switch, Dual, .6 Low(ES2087-0680), 1.1 High(ES2086-0304)
HMESA2088-0842

Air Pressure Switch, Dual, -.35 Low(ES2087-0305), -.75 High(ES2086-0841)
HMESA2088-0870

Air Pressure Switch, Dual, .6 Low(ES2087-0680), 2.0 High(ES2086-0669)
HM240T6T11

Speed Controller for Fasco Draft Inducer, 120V 1ph
HM240T6T07

Speed Controller for Fasco Draft Inducer, 230V 1ph
HM240T6T06

Speed Controller for Fasco Draft Inducer, 120/208V 1ph
HM-VB1200-5-HTCO

Integrated, Modulating, 5 to 1, use w/ HM3/4MODCOMBOVALVE(MC)
HM-VB1200-10-HTCO

Integrated, Modulating, 10 to 1, use w/ HM1/2MODCOMBOVALVE(ME)
HM-VB1200-2-HTCO-10M

Integrated, Modulating, 10 to 1, use w/ HME40-44-0001(MC<=200/ME) gas valve
HM-VB1200-2-HTCO-5M

Integrated, Modulating, use with HME50-66-0001(MC>200) gas valve
HMMCB1

Control Board. Modulating. 4 Stage. HM Units.
HMVCB1

Control Board, Modulating, 4 Stage
HMTR1-090LH15

Timer Relay Board, Maxitrol, Low Fan Start
HMTR1-090HH15

Timer Relay Board, Maxitrol, High Fan Start, HF/MH
HMSC40

Signal Conditioner with Timer Relay Integrated, default 30 sec low fire start
HMSC30-090

Signal Conditioner, Maxitrol, 90 second mid-fire hold
HMSC30-SM2AN

Signal Conditioner, for split manifold & natural gas
HM1016-527

UT, Direct replacement for 1016-427
HM1016-524

UT, Not Interchangeable w/ 1016-427 Due to updated Wiring- Direct replacement for 1016-424
HM56SERIES308

Capable Controls 24V, 10sec trial for ign, 15sec prepurge
HM35-615526-115

Fenwal 24V, 10sec trial for ign, 15sec prepurge, 15sec inter
HM7062-6176

115V, 1 spd, Draft Inducer Assembly
HM7062-5904

208V/230V, 1 spd, Draft Inducer Assembly
HM7062-6117

208V, 1 spd, Draft Inducer Assembly
HM7062-5903

115V, 1 spd, Draft Inducer Assembly
HM7062-5376

208V/230V, 2 spd, Draft Inducer Assembly
HM7062-6351

115V, 2 spd, Draft Inducer Assembly, PART# 11969B
HM7021-12230

115V, 2 spd, Draft Inducer Assembly
HM7021-11322

230V, 2 spd, Draft Inducer Assembly
70500171

115V, Electronically Controllled, Draft Inducer Assembly
HM7062-6528

115V, 1 spd, Draft Inducer Assembly
HM7062-6797

115V, 1 spd, Draft Inducer Assembly
HELOWSWITCH

Low, 1″-20″ Range, Auto Reset, Antunes #8104116203, HE,HM 500-600&by request
HEHIGHSWITCH

High, 2″-20″ Range, Manual Reset, Antunes# 8101111202, HE,HM 500-600&by request
E40-0001

Maxitrol, 1/2″ EXA Valve Part
E52.22H-0001

Maxitrol, 3/4″
E52.24H-0004

Maxitrol, 3/4″
E62.26HB-0002

Maxitrol, 1″
HMM520B

Maxitrol, 3/4″, Modulating, NAT, MD/MR/MS
HMM520BH-66

Maxitrol, 3/4″, Modulating, LP, MD/MR/MS
HMM620B

Maxitrol, 1″, Modulating, NAT, 500-600
HMM620BH

Maxitrol, 1″, Modulating, LP, 500-600
2STGGASVALVE3-4

White Rogers 36H54-404B1. 3/4.. 2 Stage w/ built-in regulator
WR36H27MOD3-4

White Rogers 36H27-B400
HM36J22-215B1

Gas Valve, White Rogers, On/Off, 1/2 x 1/2, w/ HME40-44-0001 & HM1/2MODCOMBOVALVE
HMV8944N-1012

Honeywell, 2 Stage Regulated, NAT, HMA/B500-600
HMVR8305Q4195

Honeywell, 3/4″, determine if NAT or LP spring
HMV8295A-1032

Honeywell, On/Off Soleniod, HMA/B500-600
MA Control Panel

5:1 Turndown Modulation with Induced Speed Controller Operation
MA Two-Speed Control Panel

5:1 Turndown Modulation with 2-Speed Inducer Fan Operation
MB Control Panel

10:1 Turndown Modulation with Induced Speed Controller Operation
TS Control Panel

Two-Stage Gas Control with 2-Speed Inducer Fan Operation
TN Control Panel

Two-Stage Gas Control with 1-Speed Inducer Fan Operation
SN Control Panel

On/Off Gas control with 1-Speed Inducer Fan Operation
MR Control Panel

10:1 Turndown Modulation with Induced Speed Controller Operation
WA Control Panel

5:1 Turndown Modulation with 2-Speed Inducer Fan Operation
WB Control Panel

10:1 Turndown Modulation with Induced Speed Controller Operation
HM90416B

Silicone air tubing from draft inducer to air pressure switch
HM11760B

Between Draft Inducer & Orifice Plate , sticky back, 1/8″ x 8.175″ x 8.815″ w/ PSA DC, <450
HM11761B

Between Draft Inducer & Orifice Plate, sticky back, 1/8″ x 8.907″ x 9.582 w/ PSA, 450-600
HM11928B

Between Draft Inducer/Orifice Plate assembly and Unit, 1/8″ x 8.781 x 11.179″ DC, <450
HM24VTRANS2

Transformer, Hartland Controls, 24V sec, 120 Primary; Part#HCT01E0LS04421, direct replace BE11164GAR
HM24VTRANS50

Transformer, Hartland, 120/208/240 primary, 24V@50Va sec; Part#HCT05D0LS13421, direct replace AT150
HMPSE-Y34

For all HM Units, Used on burner trays
HMPSE-Y35

For all HM Units, Used on burner trays
HM90-360

Relay, Start, White Rogers, 24V
HM90-370

Relay, Fan, White Rogers, 24V, 392 SPDT, 184-916
HMTIMERDIP

Timer, adjustable 1-1,024 sec with dip switch settings
HM1NT08L-2718

127F, Manual-reset
HM1NTO1L-4V-AM-160F

160F, Auto-reset
HM1NTO1L-4V-AM-194F

High Limit Switch, 194F, Auto-reset
HM1NTO1L-4V-AM-240F

High Limit Switch, 240F, Auto-reset
HM1NT08L-4V-FSM-350F

Rollout switch for all HM units
LIMITSWITCH300FADJ

High Limit Switch, 300F, Adjustable, PART#5D51-35High Limit Switch, 300F, adjustable, 5″ element
LIMITSWITCH330FADJ

High Limit Switch, 350F, Adjustable, PART#416-4High Limit Switch, 330F, adjustable
LIMITSWITCH210F

High Limit Switch, 210F, PART#3L09-11
LIMITSWITCH220F

High Limit Switch, 220F, PART#3L09-12
INSULTAPE.75

Silicone Orange Sponge w/ PSA, .75″Wx .11″Tk; per ft
HEINSULROPE.375

.375 high temp. insulated rope for HE/HF exhausts
HEINSULTAPE-FT

1” wide insulated adhesive high temp. tape gasket for HE/HF collector access plates
HIGHLIMITKIT11

High Temp Limit. man reset high, 11″ element, 100-250F, breaks on temp rise
HM11929B

Gasket Flue Cover. .25. x 11.875. x 31.313.. Manniglas 2000. DC
HE001

Inshot Burner 2.75 W, used on HMG400, EMG (All)
HE002

Inshot Burner 2.75 W, used on H(D,M)G075-350, HPG050-500, H(H,T)G080-440
HE006

Inshot Burner 3.25W, used on H(D,H,M,T)A/B150-600, H(D,M)T070-125, HPA150-500
HE011

Inshot Burner 3.25W, used on HMG050 LP, HPG050-500, H(H,T)G080-440