Heatco ensures INNOVATION, QUALITY, and RELIABILITY in all of our products.
Note: For the quickest service regarding parts orders/requests, please email orders@heatco.com.

Used on HDB-HH with individual BTU 200-400 adapter has 15 degree offset for 96″ cabinet

(Replaced by FA-2-6) Used in conjunction with HMFA-3 on outdoor flue riser applications with 2″ thick vestibule

Used on HMA/HDA HMB/HDB 200-400, HMG/HDG200-400 and HMD/HDD175-200 in power vent applications
HMFA-26-1 thru 9
View PDF or CAD

Used on HMA/HDA HMB/HDB200-400, HMG/HDG250-400 and HMD/HDD175-200 in power vent applications
HMFA-12-5-Insulated
View PDF or CAD

Extension used with HMFA-12 on HMT/HDT1000-1250 and HMB/HDB HMA/HDA500-600

7″ Adapter with 2.5″ offset | Used on HMA/HDA HMB/HDB 500-600 and HMT/HDT1000-1250

Used in with HMFA-3 on outdoor flue riser applications where 6″ added depth is needed

Used with HMFA-3 on indoor common flue riser precision vent applications
HMSK8
Drawings Unavailable

8in Star Cap
HMSK5
Drawings Unavailable

5in Star Cap
HMSK6
Drawings Unavailable

6in Star Cap
HMES2270-0885

(Replaced by NS2-1887-00) Air Pressure Switch, Single, 2.0
HMES2331-1037

(Replaced by NS2-1887-00) Air Pressure Switch, Single, 1.00 +/-.05″ WC
HMES2089-1011

(Replaced by NS-1888-04) Air Pressure Switch, Single, .35 +/-.05″ WC
HMES2089-0658

(Replaced by NS2-1888-02) Air Pressure Switch,Single,1.3 +/- .06
HMES2086-0708

(Replaced by NS2-1888-03) Air Pressure Switch,Single, .9 +/- .05
HMES2089-0307

(Replaced by NS2-1888-00) Air Pressure Switch,Single, 1.5 +/- .06
HMES2089-0308

(Replaced by NS2-1888-01) Air Pressure Switch,Single,1.1 +/- .05
HMES2089-1012

(Replaced by NS2-1888-05) Air Pressure Switch, Single, .60 +/-.05″ WC
HMES2090-0309

(Replaced by HMES2120-0385) Single, .5 +/- .05 PF, Indoor HE Units (obsolete – replaced w/ ES2120-0385 (NS2-1926-00))
HMES2120-0385

(Replaced by HMES2120-0385) Single, .50 +/- .05 HE Indoor units ;mfg PART#NS2-1926-00; Replaced ES2090-0309
Air Flow Pressure Switch Kit

HMRFS-4100-040(switch) and (1) HM8457K536(probe)
HMESA2088-0306

(Replaced by DNS2-1889-00) Air Pressure Switch, Dual, .35 Low(ES2087-0305), 1.1 High(ES2086-0304)
HMESA2088-0739

(Replaced by DNS2-1889-04) Air Pressure Switch, Dual, .35 Low(ES2087-0305), 1.3 High(ES2086-0679)
HMESA2093-0312

(Replaced by DNS-1889-04) Air Pressure Switch, Dual, .35 Low(ES2092-0311), 1.5 High(ES2091-0310)
HMESA2088-0678

(Replaced by DNS-1889-01) Air Pressure Switch, Dual, -.6Low(ES2087-0680), -1.3High(ES2086-0679)
HMESA2088-0706

(Replaced by DNS2-1889-03) Dual, .35 +/- .05 Low, .9 +/-.05 High
HMESA2088-0974

(OBSOLETE – Contact Engineering) Air Pressure Switch, Dual, .6 Low(ES2087-0680), .9 High(ES2086-0708)
HMESA2088-0973

(Replaced by DNS2-1889-07) Air Pressure Switch, Dual, .6 Low(ES2087-0680), 1.1 High(ES2086-0304)
HMESA2088-0842

(Replaced by DNS2-1889-05) Air Pressure Switch, Dual, -.35 Low(ES2087-0305), -.75 High(ES2086-0841)
HMESA2088-0870

(Replaced by DNS2-1889-06) Air Pressure Switch, Dual, .6 Low(ES2087-0680), 2.0 High(ES2086-0669)
HM240T6T11

Speed Controller for Fasco Draft Inducer, 120V 1ph
HM240T6T07

Speed Controller for Fasco Draft Inducer, 230V 1ph
HM240T6T06

Speed Controller for Fasco Draft Inducer, 120/208V 1ph
HM240T6T17-F

Speed Controller. 2 Speed Nimbus PART#240T6T17-F; CONFIGURABLE
HM-VB1200-5-HTCO

Integrated, Modulating, 5 to 1, use w/ HM3/4MODCOMBOVALVE(MC)
HM-VB1200-10-HTCO

Integrated, Modulating, 10 to 1, use w/ HM1/2MODCOMBOVALVE(ME)
HM-VB1200-2-HTCO-10M

Integrated, Modulating, 10 to 1, use w/ HME40-44-0001(MC<=200/ME) gas valve
HM-VB1200-2-HTCO-5M

Integrated, Modulating, use with HME50-66-0001(MC>200) gas valve
HMMCB1

Control Board, Modulating, 4 Stage (HMVCB2 is a direct replacement)
HMVCB1

Control Board, Modulating, 4 Stage (HMVCB2 is a direct replacement)
HMTR1-090LH15

Timer Relay Board, Maxitrol, Low Fan Start
HMTR1-090HH15

Timer Relay Board, Maxitrol, High Fan Start, HF/MH
HMSC40

Signal Conditioner with Timer Relay Integrated, default 30 sec low fire start
HMSC30-090

Signal Conditioner, Maxitrol, 90 second mid-fire hold
HMSC30-SM2AN

Signal Conditioner, for split manifold & natural gas
HMSC30-SM2AL

Signal Conditioner, for split manifold & propane
HM1016-527

UT, Direct replacement for 1016-427
HM1016-524

UT, Not Interchangeable w/ 1016-427 Due to updated Wiring- Direct replacement for 1016-424
HM56SERIES308

Capable Controls 24V, 10sec trial for ign, 15sec prepurge; Direct Replacement – 661031515010308
661031515010308

Capable Controls 24V, 10sec trial for ign, 15sec prepurge
HM35-615526-115

Fenwal 24V, 10sec trial for ign, 15sec prepurge, 15sec inter
HM7062-6176

115V, 1 spd, Draft Inducer Assembly; Direct replacement – NBK-20001
NBK-20001

115V, 1 spd, Draft Inducer Assembly, Direct Repl. for 7062-6176
HM7062-5904

208V/230V, 1 spd, Draft Inducer Assembly
HM7062-6117

208V, 1 spd, Draft Inducer Assembly
HM7062-5903

115V, 1 spd, Draft Inducer Assembly; Direct replacement – NBK-20691
NBK-20691

Draft Inducer Assembly.Fasco,115V,1 spd; Direct Repl. for 7062-5903
HM7062-6351

115V, 2 spd, Draft Inducer Assembly, PART# 11969B
HM7021-12230

115V, 2 spd, Draft Inducer Assembly
HM7021-11322

230V, 2 spd, Draft Inducer Assembly; Direct replacement – HM7021-13255
HM7021-13255

230V, 2 spd, Draft Inducer Assembly
70500171

115V, Electronically Controllled, Draft Inducer Assembly
HM7062-6528

115V, 1 spd, Draft Inducer Assembly
HM7062-6797

115V, 1 spd, Draft Inducer Assembly
HELOWSWITCH

Low, 1″-20″ Range, Auto Reset, Antunes #8104116203, HE,HM 500-600&by request
HEHIGHSWITCH

High, 2″-20″ Range, Manual Reset, Antunes# 8101111202, HE,HM 500-600&by request
HMV8944C-1017

Gas Valve, Honeywell, 1″, 2 Stage Regulated, LP; Replaces V8944L-1033
E53.28H-66-0002

Maxitrol, 3/4″; Replaces HME52.28HB-66-0002
EXA53.22

Maxitrol, 3/4″; Replaces HME52.22H-66-0001
E41-44-0001

Maxitrol, 1/2″; Replaces HME40-44-0001
E40-0001

Maxitrol, 1/2″ EXA Valve Part; Direct Replacement – E41-44-0001
E52.22H-0001

Maxitrol, 3/4″; Direct Replacement – EXA53.22
E52.24H-0004

Maxitrol, 3/4″; Direct Replacement – E53.24H-66-0004
E53.24H-66-0004

Maxitrol, 3/4″
E62.26HB-0002

Maxitrol, 1″
HMM520B

Maxitrol, 3/4″, Modulating, NAT, MD/MR/MS
HMM520BH-66

Maxitrol, 3/4″, Modulating, LP, MD/MR/MS
HMM620B

Maxitrol, 1″, Modulating, NAT, 500-600
HMM620BH

Maxitrol, 1″, Modulating, LP, 500-600
2STGASVALVE3-4

White Rogers 36H54-404B1. 3/4.. 2 Stage w/ built-in regulator
WR36H27MOD3-4

White Rogers 36H27-B400
HM36J22-215B1

Gas Valve, White Rogers, On/Off, 1/2 x 1/2, w/ HME40-44-0001 & HM1/2MODCOMBOVALVE
HMV8944N-1012

Honeywell, 2 Stage Regulated, NAT, HMA/B500-600
HMVR8305Q4195

Honeywell, 3/4″, determine if NAT or LP spring
HMV8295A-1032

Honeywell, On/Off Solenoid, HMA/B500-600; Direct Replacement – K3A461V
K3A461V

On/Off Solenoid, HMA/B500-600
MA Control Panel

5:1 Turndown Modulation with Induced Speed Controller Operation
MA Two-Speed Control Panel

5:1 Turndown Modulation with 2-Speed Inducer Fan Operation
MB Control Panel

10:1 Turndown Modulation with Induced Speed Controller Operation
TS Control Panel

Two-Stage Gas Control with 2-Speed Inducer Fan Operation
TN Control Panel

Two-Stage Gas Control with 1-Speed Inducer Fan Operation
SN Control Panel

On/Off Gas control with 1-Speed Inducer Fan Operation
MR Control Panel

10:1 Turndown Modulation with Induced Speed Controller Operation
WA Control Panel

5:1 Turndown Modulation with 2-Speed Inducer Fan Operation
WB Control Panel

10:1 Turndown Modulation with Induced Speed Controller Operation
HM90-362

Relay, Start, 120V – SPNO
HM90416B

Silicone air tubing from draft inducer to air pressure switch
HM11760B

Between Draft Inducer & Orifice Plate , sticky back, 1/8″ x 8.175″ x 8.815″ w/ PSA DC, <450
HM11761B

Between Draft Inducer & Orifice Plate, sticky back, 1/8″ x 8.907″ x 9.582 w/ PSA, 450-600
HM11928B

Between Draft Inducer/Orifice Plate assembly and Unit, 1/8″ x 8.781 x 11.179″ DC, <450
HM24VTRANS2

Transformer, Hartland Controls, 24V sec, 120 Primary; Part#HCT01E0LS04421, direct replace BE11164GAR
HM24VTRANS50

Transformer, Hartland, 120/208/240 primary, 24V@50Va sec; Part#HCT05D0LS13421, direct replace AT150
HMPSE-Y34

For all HM Units, Used on burner trays
HMPSE-Y35

For all HM Units, Used on burner trays
HM90-360

Relay, Start, White Rogers, 24V
HM90-370

Relay, Fan, White Rogers, 24V, 392 SPDT, 184-916
HMTIMERDIP

Timer, adjustable 1-1,024 sec with dip switch settings
HM1NT08L-2718

127F, Manual-reset
HM1NTO1L-4V-AM-160F

160F, Auto-reset
HM1NTO1L-4V-AM-194F

High Limit Switch, 194F, Auto-reset
HM1NTO1L-4V-AM-240F

High Limit Switch, 240F, Auto-reset
HM36TX26-350

Rollout switch for all HM units (replaces HM1NT08L-4V-FSM-350F)
LIMITSWITCH300FADJ

High Limit Switch, 300F, Adjustable, PART#5D51-35High Limit Switch, 300F, adjustable, 5″ element
LIMITSWITCH210F

High Limit Switch, 210F, PART#3L09-11
LIMITSWITCH220F

High Limit Switch, 220F, PART#3L09-12
INSULTAPE.75

Silicone Orange Sponge w/ PSA, .75″Wx .11″Tk; per ft
HEINSULROPE.375

.375 high temp. insulated rope for HE/HF exhausts
HEINSULTAPE-FT

1” wide insulated adhesive high temp. tape gasket for HE/HF collector access plates
HIGHLIMITKIT11

High Temp Limit. man reset high, 11″ element, 100-250F, breaks on temp rise
HM11929B

Gasket Flue Cover. .25. x 11.875. x 31.313.. Manniglas 2000. DC
HE001

Inshot Burner 2.75 W, used on HMG400, EMG (All)
HE002

Inshot Burner 2.75 W, used on H(D,M)G075-350, HPG050-500, H(H,T)G080-440
HE006

Inshot Burner 3.25W, used on H(D,H,M,T)A/B150-600, H(D,M)T070-125, HPA150-500
HE011

Inshot Burner 3.25W, used on HMG050 LP, HPG050-500, H(H,T)G080-440
UH-THERM-DIGIT

80 series 24V digital thermostat, 7 day programmable, for on/off or 2-stage heat
UH-THERM-SG

Wireless room sensor, compatible with sensi touch 2 smart thermostats to reduce hot or cold spots, senses temperature and humidity, indoor use only, wall mount or stand, connect up to 15 sensors to a single thermostat
UH-SENSI2

Sensi Touch 2 smart thermostat, black, for on/off or 2-stage heat
UH-THERM-CVR

Universal thermostat guard, clear cover, with mounting plate and mounting ring
UH-SENSI-PLT

Wallplate (black) for Sensi Touch 2
NEUTRALIZERKIT1

Condensate neutralization kit, designed to elevate the ph of condensate prior to disposasl in sewage systems, featuring a flow rate of 1.6 gallons per hour, perfect for gas-fired furnaces with a capacity of 360,000 BTUH and below
NEUTRALIZERKIT

Condensate neutralization kit, to elevate the PH of condensate before it’s drained into the sewage system, with a flow rate of 4 gallons per hour, for gas-fired furnaces with a capacity of 1,000,000 BTUH and below
NEUTRALIZERTANK

Condensate neutralization kit, designed to elevate the PH of condensate at 45 gallons per hour, for gas-fired furnaces up to 7,000,000 BTUH
UH-COND-PUMP-ASYM

Powerful 22ft maximum lift height pump featuring PVC discharge piping to the pump inlet, sturdy mounting tray secured with all-thread connections, ensuring reliable performance and condensate disposal for unit heater applications
CONCENTRIC-VENT-KIT-HORIZONTAL

Concentric vent box, exhaust cap, and fresh air intake for horizontal discharge orientation, vent pipe is not supplied, various sizes available and assembly instructions provided, applicable for category I/II vent systems
HORIZONTAL-EXHAUST-VENT-CAPS

Flue gas exhaust terminations for horizontal discharge venting terminations
CONCENTRIC-VENT-KIT-VERTICAL

Concentric vent box, exhaust cap, and fresh air intake for vertical discharge orientation, vent pipe is not supplied, various sizes available and assembly instructions provided, applicable for category I/II vent systems
VERTICAL-EXHAUST-VENT-CAPS

Flue gas exhaust terminations for vertical discharge venting terminations
DF511.66

3/4″ Modulating valve
DF55SERIES005

Direct Spark Ignition Control. 3 trials/10sec for ign, 30sec inter-purge; For use on Direct Fired
DF57SERIES005

Intermittent Pilot Control. PART# 574431030010300, 3 trials/10sec for ign, 30sec inter-purge
DFDDP-109-477

Dual Air Pressure Sensing Switch. No elect. Connector box WITH cover
DFHINGE-LATCH

Hinge Latch Compact. Hex Insert w/ Safety Catch
DFLME71.111A1PKG-PRG14

LME71.000A1 with PME71.111A1 and Plug Kit (Pre]programmed for Heatco/ Flame Safeguard
DFM-1190800-24

PILOT WITH SPARK ROD AND FLAME ROD DIRECT SPARK-EACH
DFM-1190850-24

BRUTE PILOT W/ SPARK & FLAME ROD
DFM-1200350-24

BRUTE PILOT W/ SPARK ROD & UV SCANNER MNT
DFM-1220800

REMOTE FLAME ROD
DFM-1240800

REMOTE UV SCANNER MNT.
DFM-1342-03

ADPT Pilot Spark Rod Only
DFM-1360-03

DS Flame Rod Only
DFM-18117

FRS-4-7.5 Auburn Flame Rod 7.5in Maxon. Auburn – CS13117
DFM-8456-07

SPARK PLUG WIRE BLACK PER FOOT
DFM-IGN-CONNECT

Pilot Adapter Assembly; Rajah Ignition Wire Connector
DFM-MR212D-1010-ES02

Maxitrol 1-1/4″ Mod Valve; Non-Silicone
DFM-MR212D-1212-ES02

Maxitrol 1-1/2″ Mod Valve; Non-Silicone
DFM-MR212D-88-ES02

Maxitrol 1-1/2″ Mod Valve; Non-Silicone
DFM-MR212E-1212-ES03

Maxitrol 1-1/2″ Mod Valve; Non-Silicone
DFM-MR212E-1616-ES04

Maxitrol 2″ Mod Valve; Non-Silicone
DFM-MR212G-2020-ES04

Maxitrol 2-1/2″ Mod Valve; Non-Silicone
DFM-MR212G-2424-ES05

Maxitrol 3″ Mod Valve; Non-Silicone
DFM611-88

1″ Modulator Valve






















































